Water Generation System
Water Inlet from Bore Well (Tested as per IS 10500).
Pre treatment for removal of suspended impurity and particles through multigrade filters (MGF).
Water passes through Softener followed by Ultra Filtration (UF) followed by pH
correction and anti Scaling dosing.
Reverse osmosis is done through a double pass system of 10μ Cartridge filter
Water passes through Electronic Deionization and UV to comply with USP
Standards for Purified Water. (Conductivity <1.3 uS/cm. Complying to Stage 1 at 25°c)
Purified water is used at various distribution points across the plant.
Purified Water is always maintained in a loop at a 25-30°c temperature.
General Capacity:
- Pretreatment Water System : 1700 LPH
- Purified Water System generation : 500 LPH